LPS-400 SCALE
Operation Manual
Contents subject to change without notice
Version 1.0
2006-07-26
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - Operation Manual

LPS-400 SCALE Operation Manual Contents subject to change without notice Version 1.0 2006-07-2

Page 2 - EMC compliance

x=3: 9600bps x=4: 19200bps 5.6) P6.x: RS232 communication data format x=0: 8N0 8 digits, no odd or even , 1 start bit, 1stop bit x

Page 3 - CONTENT

Display division value in different weight unit that can be used Calibration division value kg lb Lb:oz (oz) 0.0001lb Not available 0.0001lb Not

Page 4

5.15) P15.x: select which zero point will be used when powered on and weight signal is NOT within the power-on zero-point range: x=0: Choos

Page 5 - 1. FACEPLATE:

2.2) The length of the weight field will be 7 digit weight data, one for minus sign, one for decimal point, two for measure unit (e.g. “lb”, “kg”). If

Page 6 - Ⅲ. CALIBRATION:

(8) Command: all others Response: Unrecognized command <LF>? <CR><ETX> 2.5) Output status bit meaning: Table5: The statu

Page 7

800 0.1600 1.600 16.00 160.0 1600 16000 1000 0.2000 2.000 20.00 200.0 2000 20000 1200 0.2400 2.400 24.00 240.0 2400 24000 1500 0.30

Page 8

4. Ad _ _ _ --------- ADC is below min. range; 5. ¯ ¯ ¯ ¯ ¯ ---------- weight signal is too large 6. _ _ _ _ _ ------- weight signal is too small 7

Page 9

ON/OFF/ZERO + UNIT Normal weighing mode (more than 3s) Enter setup mode ON/OFF/ZERO + TARE Normal weighing mode (more than 3s) Enter calibrati

Page 10

P14.x 0, 1, 2 0 Weight signal within power-on zero point range, Choose which data as current power-on zero point; 0= current weight ; 1= calibration

Page 11 - Calibration

Declarations of compliance United States This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

Page 12

CONTENT Ⅰ. SPECIFICATIONS. ……………………………………………… P1 Ⅱ. KEY FUNCTION. ……………………………………………… P3 Ⅲ. CALIBRATION. ………………………………….……………… P6 Ⅳ. Exami

Page 13

standard SCP-01) 5. Output data: gross weight, net weight, tare weight, indicator displaying weight, weighing unit etc. ·OPE

Page 14 - all others

Ⅱ. KEY FUNCTION: 1. FACEPLATE: 2. DISPLAY SYMBOL MEANING: 2.1 Zero ◄--------The scale is at zero point and

Page 15

Hold these two buttons to show firmware version; A/D code or input working voltage of indicator. (6) + Hold these two butto

Page 16 - Ⅹ.Key Definition summary:

hold down TARE and ON/OFF/ZERO buttons to enter calibration mode. 2. When the indicator shows” CAL-?”, the scale is ready for calibration. Press TA

Page 17

the displayed data will blink. If the indicator gets reasonable data, it will calculate and store all parameters in EEPROM. And then it will auto-rese

Page 18

ON/OFF/ZERO and UNIT key until ‘SEtUP’ is shown, that means the scale is in SETUP mode. 2. This indictor has 19 kinds of parameters to be selected a